Inspection of Hot water Centrifugal Electro pumps by Vibration Analyses and IR Thermography Methods
سال انتشار: 1399
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 279
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ICME17_169
تاریخ نمایه سازی: 6 مهر 1400
چکیده مقاله:
Centrifugal electro pumps are one of the most used rotary machines in various fields and industries such as agriculture, power plants, metal forming, chemical industries, oil and gas. Besides they are used as a water circulator in homes and civil structures. Performance of pumps affect on the energy of above -mentioned industries and malfunctions could increase the energy costs significantly. Presence of faults and defects such as coupling misalignment, damages in bearings, unbalanced impeller or coupling could cause malfunctions in electro pumps. In order to eliminate these defects condition monitoring shall be performed continuously. Thermography and vibration analyses are considered as a proper methods to condition monitoring and inspection of centrifugal electro pumps. In present research condition monitoring of Centrifugal electro pump was conducted by vibration analyses and IR thermography. Three electro pump were tested. FFT spectra were plotted and studied for each pump. Meanwhile IR thermography tests were conducted. The results showed good agreement between vibration analyses and IR thermography results.
کلیدواژه ها:
نویسندگان
Milad Mohammadian
MSc, Faculty of Mechanical Eng., Tarbiat Modares University, Tehran, Iran
Davood Akbari
Asstistant Professor, Faculty of Mechanical Eng., Tarbiat Modares University, Tehran, Iran
Pouya Faraji Kalajahi
Ph.D. Student, Faculty of Mechanical Eng., Tarbiat Modares University, Tehran, Iran
Omid Ahmadinia
MSc, Maintenance Manager. Milad Tower, Tehran, Iran
Ali Fagihzadeh FiruzAbadi
BS, Inspection Expert, Milad Tower, Tehran, Iran