چکیده مقاله:

Background and Aims: Six sigma is the latest version of total quality management. It is quantitative goal for process performance. With increasing demands for improved accuracy and reliability of the results, Six Sigma is gaining increased visibility in the clinical laboratory process outcomes. The aim of study was to evaluate the quality of analytical phase performance in a clinical biochemistry laboratory by calculating sigma metrics. Materials and Methods: The study was conducted in a hospital laboratory of Bhatia Hospital, Mumbai. Mean, coefficient of variation, bias, and sigma values were calculated for ۲۴ biochemistry parameters. The guidelines used for total error allowable (TEa) values were clinical laboratory improvement amendments (CLIA), RILIBAK and college of american pathologists (CAP). Four months’ internal and external quality control data were extracted for the following parameters-albumin, alkaline phosphatase (ALP), alanine aminotransferase (ALT), amylase, aspartate aminotransferase (AST), bilirubin direct, bilirubin total, Ca, cholesterol, creatine kinase (CK), creatinine, triglycerides (TG), Uric acid (UA), unsaturated iron binding capacity (UIBC), urea, gamma-glutamyl transferase (GGT), glucose, high-density lipoproteins (HDL), iron, lactate dehydrogenase (LDH), lipase, Mg, phosphorus and total protein. Results: Albumin, ALP, AST, ALT, amylase, bilirubin total, Ca, cholesterol, CK, creatinine, TG, uric acid, GGT, glucose, iron, LDH, lipase, Mg, Phosphorus, total protein showed the performance of more than six Sigma for both level of controls. Bilirubin direct, Urea, for level ۱; UIBC, urea, HDL for level ۲ showed sigma from ۳-۶. Conclusions: Based upon sigma metrics, laboratory quality control strategy can be planned and reevaluated for continuous monitoring and improvement of test methods.

نویسندگان

Shalini N. Maksane

Department of Biochemistry, Bhatia Hospital, Mumbai, Maharashtra, India

Rupali Parikh

Department of Pathology, Bhatia Hospital, Mumbai, Maharashtra, India.

Lakshmi Vaswani

Department of Pathology, Bhatia Hospital, Mumbai, Maharashtra, India.

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • . Coskun A, Inal T, Unsal I, Serteser M. Six ...
  • . Pacey AA. Quality assurance and quality control in the ...
  • . Core Laoratory. Six sigma. Available at: https://www.abbottdiagnostics.com/en-us/support/six-sigma.html. [Accessed date: ...
  • . Bendell T. A review and comparison of six sigma ...
  • . Harry MJ, Schroeder R. The Breakthrough Management Strategy Revolutionizing ...
  • . World Health Organization. Laboratory quality management system: handbook. Available ...
  • . World Health Organization. Quality assurance. Available at: http://www.who.int/diagnostics _laboratory/quality/en/. ...
  • نمایش کامل مراجع