Impact of Prolonged Fraction Delivery Time Modelling Stereotactic Body Radiation Therapy with High Dose Hypofractionation on the Killing of Cultured ACHN Renal Cell Carcinoma Cell Line
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 7، شماره: 3
سال انتشار: 1396
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 79
فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-7-3_002
تاریخ نمایه سازی: 30 دی 1402
چکیده مقاله:
Introduction: Stereotactic body radiotherapy delivers hypofractionated irradiation with high dose per fraction through complex treatment techniques. The increased complexity leads to longer dose delivery times for each fraction. The purpose of this study is to investigate the impact of prolonged fraction delivery time with high-dose hypofractionation on the killing of cultured ACHN cells.Methods and Materials: The radiobiological characteristics and repair half-time of human ACHN renal cell carcinoma cell line were studied with clonogenic assays. A total dose of ۲۰ Gy was administered in ۱, ۲ or ۳ fractions over ۱۵, ۳۰ or ۴۵ min to investigate the biological effectiveness of radiation delivery time and hypofractionation. Cell cycle and apoptosis analysis was performed after ۳-fraction irradiation over ۳۰ and ۴۵ min.Results: The α/β and repair half-time were ۵.۲ Gy and ۱۹ min, respectively. The surviving fractions increased with increase in the fraction delivery time and decreased more pronouncedly with increase in the fraction number over a treatment period of ۳۰ to ۴۵ min. With increase in the total radiation time to ۳۰ and ۴۵ min, it was found that with the same total dose, ۲- and ۳-fraction irradiation led to more cell killing than ۱-fraction irradiation. ۳-fraction radiation induced G۲/M arrest, and the percentage of apoptotic cells decreased when the fraction delivery time increased from ۳۰ min to ۴۵ min.Conclusion: Our findings revealed that sublethal damage repair and redistribution of the cell cycle were predominant factors affecting cell response in the prolonged and hypofractionated irradiation regimes, respectively.
کلیدواژه ها:
Hypofractionation ، Prolonged Fraction Delivery Time ، Renal cell carcinoma ، Stereotactic Body Radiotherapy ، Sublethal Damage Repair
نویسندگان
M Khorramizadeh
Department of Medical Physics, Faculty of Medicine, Dezful University of Medical Sciences, Dezful, Iran
A Saberi
Department of Medical Genetics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
M Tahmasebi–birgani
Department of Medical Physics, Faculty of Medicine, Dezful University of Medical Sciences, Dezful, Iran
P Shokrani
Department of Medical Physics and Medical Engineering, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
A Amouhedari
Department of Radiation Oncology, Milad Hospital, Isfahan, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :