The Study of Performance Comparison of Flat Plate and Evacuated Tube Collectors for Domestic Hot Water Heating Systems in Kerman

سال انتشار: 1397
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 498

فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

CLEANENERGY06_018

تاریخ نمایه سازی: 1 دی 1398

چکیده مقاله:

This study represents a year round energy performance of two solar water heater (SWH) systems with 4m2 flat plate collector (FPC) and evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on monthly and yearly basis. The obtained results showed that for an annual total solar insolation of 2056kWhm2 , the total of 3577kWhy 1 and 4201kWhy 1 heat energy were collected by 4m2 FPC and ETC systems, respectively. The annual average efficiency by FPC system was 43%, while its annual solar fraction was 50%. The ETC system had 51% efficiency with 58% solar fraction. The economic analysis showed that both solar water heating system are not economically viable under prevailing costs in Iran. Furthermore, according to the obtained results the FPCs are more favorable than the ETCs due to its economic analysis and energy performance. These results provide useful information for households and policy makers.

نویسندگان

Hadi Farzan

Mechanical Engineering Department, Higher Educational Complex of Bam, ۷۶۶۱۵-۳۱۴, Bam, Iran